Menu

MEP Trades

Commercial HVAC and Mechanical Estimating Services

Tribuild takes off HVAC and mechanical by system: ductwork by weight and area, piping by size and linear foot, and equipment counted by tag, with air devices, controls, and insulation carried so the full mechanical scope is priced.

Mechanical bids ride on ductwork weight and piping length. Tribuild takes off HVAC and mechanical by system, duct by weight and area by gauge and pressure class, hydronic and refrigerant piping by size and linear foot, and equipment counted by tag from the schedules.

Air devices, dampers, controls, insulation, and supports are carried per the documents, TAB is allowed by device count, and every deliverable ships with documented assumptions your team can price and defend.

What we estimate for hvac and mechanical

Ductwork

Supply, return, and exhaust duct by weight/area by gauge and pressure class.

Duct fittings

Elbows, transitions, and taps quantified with the duct runs.

Air devices

Diffusers, registers, and grilles counted by type from the schedule.

Dampers

Fire, smoke, volume, and balancing dampers counted by type.

HVAC equipment

RTUs, AHUs, VAVs, fans, and split systems counted by tag from the schedule.

Controls

Control devices and points counted/allowed per the sequence and schedule.

Hydronic piping

Chilled- and hot-water piping by size and linear foot with fittings.

Refrigerant piping

Refrigerant line sets by size and linear foot.

Steam and condensate

Steam and condensate piping by size and linear foot where applicable.

Insulation

Duct and pipe insulation by area and linear foot per the spec.

Supports

Hangers, supports, and seismic bracing by allowance/linear foot.

Accessories

Access doors, flex, curbs, and specialties counted by unit.

Testing and balancing

TAB scope allowance per the number of devices/systems.

Demolition

Removal of existing mechanical quantified for disposal.

Services available for this trade

What you receive

  • Quantity takeoff workbook by mechanical system
  • Ductwork by weight/area and gauge
  • Piping by system, size, and linear foot
  • Equipment and air-device counts by tag/type
  • Insulation and accessory quantities
  • Scope notes, assumptions, and qualification notes

Software and platforms

Trimble AutoBid MechanicalTrimble Estimation MEPRevitAutoCADBluebeam

Project experience

HealthcareEducationCorporate officesIndustrialHospitalityGovernmentMultifamily

How it works

  1. 1

    You submit drawings, specifications, addenda, and bid information.

  2. 2

    Tribuild reviews the scope and delivery requirements.

  3. 3

    The project is assigned to the appropriate estimator or team.

  4. 4

    Questions and clarifications are documented where necessary.

  5. 5

    The deliverable is reviewed under Tribuild's applicable quality-control process.

  6. 6

    The project is delivered through the Tribuild portal or an approved delivery method.

  7. 7

    Revisions and addenda are managed under the applicable service agreement.

Quality control

  • Systems reconciled against mechanical plans and equipment schedules
  • Ductwork gauge/pressure class confirmed against the spec
  • Piping measured by system and size
  • Equipment and devices counted from schedules
  • Addendum tracking against mechanical revisions

Frequently asked questions

Mechanical plans, equipment and air-device schedules, control sequences, piping and duct details, and specifications. Schedules drive equipment and device counts.

By weight and area by gauge and pressure class, with fittings carried, so fabrication and installation labor are priced correctly.

Controls are counted/allowed per the sequence and schedule, and testing-and-balancing is carried as an allowance per device/system count.

Yes, each piping system is measured on its own by size and linear foot with the appropriate insulation.